EBLOne, the new standard

The innovative EBLOne control unit sets a new standard in one-loop fire detection systems with its compact size, contemporary design and the most intuitive user interface.
Learn more

Panasonic high-end fire alarm system for Metsä Fibre bioproduct mill

Metsä Fibre’s new bioproduct mill, the most efficient wood industry in the northern hemisphere, has been equipped with Panasonic’s fire alarms solutions to meet its demanding requirements for a reliable detection system.
Learn more

Gateway, tools for easy interaction

Easy interaction with EBL fire alarm systems has always been a main driver in our innovation work. With Gateway 5088 hardware platform we have continuously developed new applications and powerful functions.
Learn more

Control & Indication Equipment

EBL512 G3

EBL512 G3

EBL512 G3 is the powerful and flexible addressable fire alarm system for a unique early detection with four COM loops and 1020 addresses.

System EBLOne

System EBLOne

EBLOne, the control unit that sets a new standard in one-loop fire detection systems.

EBLWin

EBLWin

EBLWIn is the easy-to-use software for planning, commissioning and maintenance of both EBL512 G3 and EBLOne. Auto addressing as well as manual address setting available.

Detectors & bases

Isolator detectors

Isolator detectors

Addressable smoke and multi detectors with built-in short circuit isolator and true Artificial Intelligence for minimum nuisance alarms.

Detectors without isolator

Detectors without isolator

A wide range of state-of-the-art addressable detectors for highest security, such as smoke, heat, multi detector and multi detector with CO.

Intrinsically safe detectors

Intrinsically safe detectors

Addressable intrinsically safe detectors for fire detection in hazardous (EX) areas. Complete with barrier unit and back box for highest IP classification.

Conventional detectors

Conventional detectors

Find here both standard smoke detectors with AI solutions as well as the most comprehensive series of waterproof detectors for high temperature ranges.

Accessories

Accessories

A variety of accessories that makes the installation of Panasonic detectors easy, as well as protect them against condensation, low temperatures or physical damage.

Special detectors

Special detectors

Detection for special applications with flame detectors, beam detectors with industry leading optics and advanced linear heat detection with fiber optics.

Wireless

Smoke detector 4611

Smoke detector 4611

Fast, cost effective and reliable addressable wireless smoke detector for buildings where it is difficult to hide cables and where extensions are required.

Manual call point 4614

Manual call point 4614

Wireless manual call point with up to 170 m transmission range (open air) and 6 years battery life.

Base station 4620

Base station 4620

Addressable base station. Highly flexible: up to 4 base stations per COM loop and up to 16 wireless units on each base station enabling up to 256 units per CIE.

Local alarm acknowledge unit 4645

Local alarm acknowledge unit 4645

The wireless LAAU eliminates unnecessary alarms to the fire brigade. Combine with wireless smoke detector for the most flexible and secure protection of apartments.

Sniffer 4613

Sniffer 4613

Sniffer tool for verification of the wireless installation quality during the planning, installation, and commissioning phases.

Display unit

Display unit 5054

Display unit 5054

Versatile unit with a 10” colour touch screen including several innovative selectable user applications.

Metal cabinet 5055

Metal cabinet 5055

Metal cabinet for build-in of the display unit. Recommended for fire brigade panel applications or in public locations.

Aspirating detectors

Grizzle aspirating smoke detector AE2010G-P

Grizzle aspirating smoke detector AE2010G-P

All in One Aspect Grizzle aspirating smoke detector, extremely reliable in humid and dusty environments.  Self-calibrating for the easiest configuration available. Detection classes B and C

Lazeer aspirating smoke detector AE2010L-P

Lazeer aspirating smoke detector AE2010L-P

All in One Aspect Lazeer aspirating smoke detector, developed for early warning in clean rooms, data centers or laboratories. Self-calibrating for the easiest configuration available Detection class A.

PipeDraw

PipeDraw

Experience this easy-to-use PC program for the design of even the most complex aspiration systems. Multiple functions like the automatic calculation of the pipes and a materials list for convenient planning.

Accessories

Accessories

Connectivity & software

Gateway 5088

Gateway 5088

The Gateway enables the connection of your EBL fire alarm system to the outside world. You can use it for remote monitoring and control of the EBL system as well as to connect to any 3rd party security or building management system.

EBL App

EBL App

EBLApp is a powerful smartphone tool for maintenance and service with several mobile applications. It allows for true one-man testing with report generation, as well as check loop and verification of the system.

EBL Graphics

EBL Graphics

EBLGraphics creates a graphical representation of your fire alarm system. Extremely fast setup, by reuse of the commissioning file. Drawings and symbols are easily customized to fit any need. Once in place, you can interact directly in the drawings.

EBLCloud

EBLCloud

Coming soon.

EBLnet 5097

EBLnet 5097

EBLNet is a Panasonic developed open protocol to receive data and events from the EBL system via TCP/IP, that performs operations in a security management system.

Exit & emergency lights

Exit light

Exit light

Panasonic’s exit lights are addressable and thereby fully integrated with the fire alarm system. The adaptive exit lights can dynamically change to indicate the safest evacuation route possible.

Emergency light

Emergency light

Addressable emergency lights that are fully integrated in the fire alarm system. Available with round lens for open areas and asymmetric for corridors, as well as units for outdoor and high humidity installations.

Power supply

Power supply

A power box provides the emergency and exit lights with power separately which makes it possible to maintain the length of the loop and still add many luminaires.

I/O Units

Multipurpose I/O unit 4461

Multipurpose I/O unit 4461

Addressable multipurpose I/O unit with built-in isolator. The unit supports auto-addressing and comes is an IP65 housing.

2 inputs unit 4462

2 inputs unit 4462

Addressable unit with dual monitored inputs and built-in isolator. The unit supports auto-addressing and comes is an IP65 housing

230 VAC Relay output unitt 4460

230 VAC Relay output unitt 4460

Addressable 230 VAC relay output unit for control fire hatches and other fire protection equipment. The unit supports auto-addressing and comes is an IP66/67 housing.

Power supply 4466

Power supply 4466

Addressable 230V power supply with built-in short-circuit isolator and space for two expansion boards with voltage outputs and/or loop expander.

COM-loop repeater 4585

COM-loop repeater 4585

The unique COM-loop repeater gets a new loop with full power and distance with the greatest adaptability for the growing needs of the installation.

2 voltage outputs board 4464

2 voltage outputs board 4464

This unit is mounted as an expansion board inside the external power supply and provides two monitored voltage outputs (2 A each) and a special fire door closing function.

Local alarm acknowledge unit 4445

Local alarm acknowledge unit 4445

It avoids unnecessary alarms to the fire brigade. Combine with wired detectors and sounder base or wireless detectors for optimal apartment protection.

2 voltage outputs unit 3364

2 voltage outputs unit 3364

Voltage output unit with two programmable and supervised outputs, ideal for alarm devices or make use of the special fire door function.

Modular sprinkler control box

Modular sprinkler control box

Modular sprinkler control box for test and disablement. With IP65-rated protection and monitored input. Available in 1, 2, or 3 sprinkler zone options.

Alarm devices & indicators

Alarm devices

Alarm devices

Panasonic offers a range of addressable alarm devices both visual and audible, with isolator to ensure a secure alarm always: wall and ceiling VADs and sirens as well as combined VAD and siren.

Indicators

Indicators

External LED indicators for wall or flush mounting. Available both addressable and conventional models. Additionally, there are programmable indicators for mounting between bases or sounder bases and detectors.

Manual call points

Manual call point 4433

Manual call point 4433

Addressable manual call point with protection against accidental operation and built-in short circuit isolator

Pulsador manual de alarma 4439

Pulsador manual de alarma 4439

Pulsador manual de alarma direccionable con protección contra operaciones accidentales y aislador de cortocircuito incorporado.

Tools

Address setting tool 4414 E

Address setting tool 4414 E

Address setting tool for a fast and easy to use address setting of all types of COM loop units.

Loop tester 1105

Loop tester 1105

Loop tester is useful to avoid trouble shooting in the commissioning phase. It can also be used for auto-addressing of loop units and the readouts can be combined to a complete SSD.

TLON manager kit 5095

TLON manager kit 5095

Software & hardware for the creation and installation of a TLON network, that connects up to 30 EBL512 G3 panels in a redundant network.

}

Find your distributor

Contact your nearest Panasonic distributor who will assist you in providing the most suitable fire alarm solution for your installation.

Search